CSA Certifications
Class: 4823 02 Appliance Controls
Maximum Ratings |
|||||
Model Code | Voltage | Current (Amperes) |
Load Type | Temperature (C) |
Endurance (# of Cycles) |
A, AA * | 120 VAC | 3 | Resistive | 150 | 100000 |
A, AA * | 240 VAC | 1.5 | Resistive | 150 | 100000 |
A1, AA1 | 120 VAC | 3 | Resistive | 150 | 100000 |
A1, AA1 | 240 VAC | 1.5 | Resistive | 150 | 100000 |
A2, AA2, A2R, AA2R | 120 VAC | 4 | Resistive | 200 | 100000 |
A2, AA2, A2R, AA2R | 240 VAC | 2 | Resistive | 200 | 100000 |
-A2, -AA2 | 120 VAC | 4 | Resistive | 200 | 100000 |
-A2, -AA2 | 240 VAC | 2 | Resistive | 200 | 100000 |
A3, AA3 | 120 VAC | 6 | Resistive | 200 | 100000 |
A3, AA3 | 240 VAC | 3 | Resistive | 200 | 100000 |
C, CR | 120 VAC | 3 | Resistive | 150 | 100000 |
C, CR | 240 VAC | 1.5 | Resistive | 150 | 100000 |
CH | 120 VAC | 3 | Resistive | 200 | 100000 |
CH | 240 VAC | 1.5 | Resistive | 200 | 100000 |
E ** | 120 VAC | 2 | Resistive | 90 | 100000 |
J(A) | 120 VAC | 5 | Resistive | 150 | 100000 |
J(A) | 240 VAC | 4 | Resistive | 150 | 100000 |
J(D) | 120 VAC | 8 | Resistive | 150 | 100000 |
J(D) | 240 VAC | 8 | Resistive | 150 | 100000 |
J-2 | 120 VAC | 15 | Resistive | 160 | 6000 |
K, KH, KR | 120 VAC | 2 | Resistive | 200 | 100000 |
K, KH, KR | 240 VAC | 2 | Resistive | 200 | 100000 |
* Has been evaluated in the end product (heating pads) with acceptable results.
** Has been evaluated by CSA for use in heating pad applications.
Category: Motor Protectors
Note: All motor proctors have been evaluated for limited short circuit.
Maximum Ratings | ||||||
Model Code | Voltage | Full Load (Amperes) |
Locked Rotor (Amperes) |
Load Type | Endurance (# of Cycles) |
HP |
A | 120 VAC | 3 | 18 | Inductive | 2000 | – |
A | 240 VAC | 1.5 | 9 | Inductive | 2000 | – |
B | 120 VAC | 2 | 12 | Inductive | 2000 | – |
B | 240 VAC | 1.4 | 8 | Inductive | 2000 | – |
C, CH | 120 VAC | 1 | 6 | Inductive | 2000 | – |
C, CH | 240 VAC | 0.7 | 4 | Inductive | 2000 | – |
F | 120 VAC | 2 | 12 | Inductive | 2000 | – |
F | 240 VAC | 1.4 | 8 | Inductive | 2000 | – |
F-1 | 120 VAC | 2 | 12 | Inductive | 2000 | – |
F-1 | 240 VAC | 1.4 | 8 | Inductive | 2000 | – |
F-2 | 120 VAC | 2 | 12 | Inductive | 2000 | – |
F-2 | 240 VAC | 1.4 | 8 | Inductive | 2000 | – |
G | 120 VAC | 0.7 | 4 | Inductive | 2000 | – |
G | 240 VAC | 0.3 | 2 | Inductive | 2000 | – |
J(B) | 120 VAC | 7 | 42 | Inductive | 2000 | – |
J(B) | 240 VAC | 3.7 | 22.2 | Inductive | 2000 | – |
J(D) | 120 VAC | 7 | 42 | Inductive | 2000 | – |
J(D) | 240 VAC | 3.7 | 22.2 | Inductive | 2000 | – |
J(F) | 120 VAC | 7 | 42 | Inductive | 2000 | – |
J(F) | 240 VAC | 3.7 | 22.2 | Inductive | 2000 | – |
J(H) | 120 VAC | 7 | 42 | Inductive | 2000 | – |
J(H) | 240 VAC | 3.7 | 22.2 | Inductive | 2000 | – |
J(J) | 120 VAC | 7 | 42 | Inductive | 2000 | – |
J(J) | 120 VAC | 3.7 | 22.2 | Inductive | 2000 | – |
J(S) | 120 VAC | 7 | 42 | Inductive | 2000 | – |
J(S) | 240 VAC | 3.7 | 22.2 | Inductive | 2000 | – |
K, KH | 120 VAC | 1 | 6 | Inductive | 2000 | – |
K, KH | 240 VAC | 0.5 | 3 | Inductive | 2000 | – |
W 030 | 115 VAC | 13.8 | 50 | Inductive | 2000 | 3/4 |
W 030 | 230 VAC | 6.9 | 37 | Inductive | 2000 | 3/4 |
W 100 | 115 VAC | 13.8 | 50 | Inductive | 2000 | 3/4 |
W 100 | 230 VAC | 6.9 | 37 | Inductive | 2000 | 3/4 |
W 200 | 115 VAC | 13.8 | 50 | Inductive | 2000 | 3/4 |
W 200 | 230 VAC | 6.9 | 37 | Inductive | 2000 | 3/4 |
W 300 | 115 VAC | 13.8 | 50 | Inductive | 2000 | 3/4 |
W 300 | 230 VAC | 6.9 | 37 | Inductive | 2000 | 3/4 |
W 400 | 115 VAC | 13.8 | 50 | Inductive | 2000 | 3/4 |
W 400 | 230 VAC | 6.9 | 37 | Inductive | 2000 | 3/4 |